Digital Residual Chlorine Sensor Industrial Online Residual Chlorine Meter Electrode Digital RS485 Free Chlorine Sensor

Product Details
Customization: Available
After-sales Service: Lifelong
Warranty: 1 Year
Still deciding? Get samples of US$ 253/Piece
Request Sample
Gold Member Since 2024

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Importers and Exporters
The supplier has import and export rights
High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
to see all verified strength labels (15)
  • Digital Residual Chlorine Sensor Industrial Online Residual Chlorine Meter Electrode Digital RS485 Free Chlorine Sensor
  • Digital Residual Chlorine Sensor Industrial Online Residual Chlorine Meter Electrode Digital RS485 Free Chlorine Sensor
  • Digital Residual Chlorine Sensor Industrial Online Residual Chlorine Meter Electrode Digital RS485 Free Chlorine Sensor
  • Digital Residual Chlorine Sensor Industrial Online Residual Chlorine Meter Electrode Digital RS485 Free Chlorine Sensor
  • Digital Residual Chlorine Sensor Industrial Online Residual Chlorine Meter Electrode Digital RS485 Free Chlorine Sensor
  • Digital Residual Chlorine Sensor Industrial Online Residual Chlorine Meter Electrode Digital RS485 Free Chlorine Sensor
Find Similar Products

Basic Info.

Model NO.
CLDS710
Display
Digital
Portable
Non Portable
Appliance
Food Analysis, Medical Research
Certification
ISO9001, CE
Item
Digital Residual Chlorine Sensor
Model No.
Clds710
Power/Signal Output
9~36VDC/RS485 Modbus RTU 4~20mA(Optional)
Measurement Method
Potentiostatic
Housing Material
Glass+POM
Waterproof Grade
IP68
Measurement Range
0-2mg/L;0-10mg/L;0-20mg/L
Accuracy
±1%F.S
Pressure Range
≤0.3MPa
Temperature Compensation
Ntc10K
Temperature Range
0-80ºC
Calibration
Water Sample, Chlorine-Free Water and Standard Li
Connection Methods
4 Core Cable
Cable Length
Standard 10m Cable or Extended to 100m
Installation Thread
Pg13.5
Transport Package
A5 Export Standard Carton
Trademark
OEM
Origin
China

Product Description

CLDS710 Digital Residual Chlorine Sensor 

Electrode principle characteristics:
Constant voltage principle electrode is used to measure residual chlorine or hypochlorous acid in water. The constant voltage measurement method is to maintain a stable potential at the electrode measuring end, and different measured components produce different current intensities under this potential. It consists of two platinum electrodes and a reference electrode to form a micro current measurement system. The residual chlorine or hypochlorous acid in the water sample flowing through the measuring electrode will be consumed. Therefore, the water sample must be kept flowing continuously through the measuring electrode during measurement.

The constant voltage measurement method uses a secondary instrument to continuously and dynamically control the potential between the measuring electrodes, eliminating the inherent resistance and oxidation-reduction potential of the measured water sample, so that the electrode can measure the current signal and the measured water sample concentration A good linear relationship is formed between them, with a very stable zero point performance, ensuring accurate and reliable measurement.


The constant voltage electrode has a simple structure and a glass appearance. The front end of the online residual chlorine electrode is a glass bulb, which is easy to clean and replace. When measuring, it is necessary to ensure that the water flow rate through the residual chlorine measuring electrode is stable.

Residual chlorine or hypochlorous acid. This product is a digital sensor that integrates electronic circuits and microprocessors inside the sensor, referred to as digital electrode.

 
Digital Residual Chlorine Sensor Industrial Online Residual Chlorine Meter Electrode Digital RS485 Free Chlorine SensorDigital Residual Chlorine Sensor Industrial Online Residual Chlorine Meter Electrode Digital RS485 Free Chlorine Sensor

Residual chlorine digital electrode sensor (RS-485) Features

1. Power supply and output isolation design to ensure electrical safety

2. Built-in protection circuit for power supply and communication chip, strong anti-interference ability

3. With comprehensive protection circuit design, it can work reliably without additional isolation equipment

4. The circuit is built inside the electrode, which has good environmental tolerance and easier installation and operation

5. RS-485 transmission interface, MODBUS-RTU communication protocol, two-way communication, can receive remote commands

6. The communication protocol is simple and practical and extremely convenient to use

7. Output more electrode diagnostic information, more intelligent

8. The internal integrated memory can still memorize the stored calibration and setting information after power off

9. POM shell, strong corrosion resistance, PG13.5 thread, easy to install.



Application:
Drinking water: ensuring reliable disinfection
Food: to ensure food safety, sanitary bag and bottle methods
Public works: detection of residual chlorine
Pool water: efficient disinfectant
 
No additional instrument is required, 485 signal transmission, no interference on site, easy to integrate into various systems, and effectively reduce related use costs.
The electrodes can be calibrated in the office or laboratory, and replaced directly on site, without additional on-site calibration, which greatly facilitates later maintenance
Calibration information record is stored in electrode memory.

 

Technical parameters:

CLDS710 Digital Residual Chlorine Sensor Electrode

Model NO.: CLDS710

Power/Signal Output: 9~36VDC/RS485 MODBUS RTU 4~20mA(Optional)

Measurement method: Potentiostatic

Housing material: Glass+POM

Waterproof grade: IP68

Measurement range: 0-2mg/L;0-10mg/L;0-20mg/L

Accuracy: ±1%F.S

Pressure range: ≤0.3Mpa

Temperature compensation: NTC10K

Temperature range: 0-80ºC

Calibration: Water sample, chlorine-free water  and standard liquid

Connection methods: 4 core cable

Cable length: Standard 10m cable  or extended to 100m

Installation thread: PG13.5

Application: Tap water, pool water, etc
 

Production:

Digital Residual Chlorine Sensor Industrial Online Residual Chlorine Meter Electrode Digital RS485 Free Chlorine Sensor

Application:

Digital Residual Chlorine Sensor Industrial Online Residual Chlorine Meter Electrode Digital RS485 Free Chlorine Sensor

Company profile:
We-Suzhou Skying Control Technology Co., Ltd. is a leading manufacturer, supplier and exporter of water analysis instruments.
We specialize in the production water quality analysis instruments and various sensors: 
1. Online PH/ORP meter and sensors; Conductivity meter, TDS meter, dissolved oxygen meter,
    fluorescence dissolved oxygen meter, residual chlorine analyzer, chlorine dioxide analyzer,
    acid-base salt analyzer, dissolved ozone meter, nitrate meter, turbidity meter,
2. Multi-parameter water quality analysis instrument controller, portable water quality analysis instrument
3. Digital online controllers and sensors, (PH/ORP/Conductivity/TDS/dissolved oxygen/residual chlorine......)
4. COD sensor
5. Pen type
6. Portable


The product range covers industrial, handheld, laboratory, aquarium, agriculture and other application fields.
In addition, we also provide instrument-related products such as instrument protection boxes, integrated systems, and control panels.
Products are widely used in power plants, petrochemicals, mining and metallurgy, environmental protection water treatment, light industry electronics, water plants and drinking water pipe networks, food and beverages, hospitals, hotels, aquaculture, new agricultural planting and biological fermentation processes and other industries.

Excellent Quality, best price, excellent after-sales service and technical support, as well as good communication with customers, that makes us be preferred the partner for many overseas customers.

 Digital Residual Chlorine Sensor Industrial Online Residual Chlorine Meter Electrode Digital RS485 Free Chlorine SensorDigital Residual Chlorine Sensor Industrial Online Residual Chlorine Meter Electrode Digital RS485 Free Chlorine Sensor

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now